Buku Mantra & Sihir
Peralatan SihirTrik Sihir
  • 🗺️Resep Sihir
  • 🅿️PARKING SYSTEM
    • 🏞️CPMS & POS
      • 🏂Showcase
        • QR BAG - Asia Parking
        • Update lisensi sistem parkir CPMS
        • FINNET-QRIS
        • Settlement Setoran
        • Size
      • 🧩Releases
    • Dashboard CPMS
    • 🎫E-Ticketing
    • 🚘Carlist
      • Installation
    • 🪨Harrcon System
      • Instalasi Software
    • 🗻Reserve Parking Standalone (BROMO)
      • ✍️Wiring HPPC Controller
      • 📒Manual Bromo
    • 🔓Parking Lock
      • IOT Parking Lock V.1.0.0 1
  • 🏡CASS
    • 🎗️CASS Premium
      • 🐟Aplikasi putar iklan
    • 🦕CASS VIP
      • Struktur Menu GAMA
      • Manual GAMA CASS VIP
    • 📮Cass Center
      • 🗄️Mini CASS
    • 🏕️Add On Tamu
      • 🌅Summarecon Gold Member
      • ⛵Open Gate Asia Parking
      • 🛡️Setup Server Paramount
      • 🔥API Paramount
      • 🔥API Citra Garden Puri
      • 🔥API Emerald Sepatan
      • 🔥API Neo Catalonia
      • 🔥API Castilla
  • 🛅GATE
    • 💣BOOM
      • 🚪Access PRO
        • Switch MPH1 ke MPH2 dengan Tool
      • 🚪MX
      • 🚪GS-001
        • ✍️Wiring
        • ⚙️Setting Parameters
      • 🚪GS-002
  • 🔢DDS
    • 6️⃣DDS Link
    • 7️⃣DDS LOOP
      • DDS Counter ICPCON
      • AUTOSTART SERVICE ICPCO
      • GOP Service Loop
      • SOP
  • 🎥CCTV
    • 📷LPR
      • Upgrade Firmware LPR TCG227 (SAHP227)
      • DS-TCG227
    • ⏺️NVR
  • 🚢SENSOR
    • 🤳Radar
      • Instalasi Radar
      • Wiring Diagram
      • Setting Parameter
    • 🪜Laser
      • 🛣️Comark LSR2001
  • 📶NETWORKING
    • 📻Radio
      • ♟️UBIQUITI
    • 🛶Mikrotik
      • Monitoring perangkat lewat Telegram [NETWATCH]
  • 🅰️AKE
    • 🚦MPGS
      • SDC-22NRS Data Server Simple Instructions
      • Adding Zonal Controller CUC-14RR and Ultrasonic Detector in DMS
      • MPGS Software Debug Manual Ultrasonic Solution
      • MPGS System API v3.6
      • Buat Map MPGS dengan Deep Zoom Composer
      • LED 18 Debug Tool
  • 🥪Reader
    • ♋Scanner QR
      • 🇮🇩Scanner SAP
      • 🦓Scanner Zebra
        • General
      • 🌒Scanner Codeshop
        • Format Code
    • 🍡DG-800
      • Features
      • Specification
      • Indicator Status & Default Setting Parameters
      • Wiring Diagram
      • Operation Instruction
  • 🎛️CONTROLLER
    • FALCO
      • [FALCO] This account has been locked or disabled for security reasons !
      • General
  • 🪄Trik Sihir
    • SupportX Apps
      • Panel Admin
        • Reports
          • Summary Outstanding
      • Panel Support
      • Changelogs
    • UnFaedah
      • Rescuezilla – Backup & Restore Software
    • Windows
      • Install Offline NET Framework 3.5 on Windows
      • Failed to install .Net Framework due to certificate could not verified
      • Meinberg NTP
      • 2 Cara Aktivasi Windows 10 Permanen GRATIS (100% Work)
      • Page 1
    • CentOS 7
      • Install Apache Web Server di CentOS 7
      • Install PHP 7.4 di CentOS 7
      • Install Mariadb 10.4 di CentOS 7
      • Open Port MySQL dan SSH
      • Install Server CentOS 7, MySQL with GUI
      • Can't find a valid base url for repo: base/7/x86_64
      • Setup Server Manless
    • Ubuntu
      • Install MySQL 5.7.* on Ubuntu 22.04, 24.04 dan 25.04
Powered by GitBook
On this page
  • Log In System
  • Importing the Parking Base Map
  • Drawing the Map
  • Save Data and Add Floors
  • Edit Parking Space
  • Editing LED Display
  • Bingding the Logic Area
  • Equipment Parameter Configuration in DMS
  • LED Indoor(Non 18 Type) LED Display
  • Zonal Controller Debugging
  • Adding Ultrasonic Detector in the Map
  • Adding the Zonal Controller to DMS
  • Adding Loop Detector in the Map
  • Configuration of RS485-to-Ethernet Converter for Ultrasonic

Was this helpful?

  1. AKE
  2. MPGS

MPGS Software Debug Manual Ultrasonic Solution

PreviousAdding Zonal Controller CUC-14RR and Ultrasonic Detector in DMSNextMPGS System API v3.6

Last updated 1 year ago

Was this helpful?

Log In System

  • Click “Not Listed?” in the frame above to enter the account and password input interface.

Account : root

Password : ake@centos73

  • After entering the system, open the Firefox browser

  • Enter the URL 127.0.0.1:8180, it may not be opened because the program has not yet started. The slowest is usually 10 minutes later, and more ctrl + f5 force refresh.

  • Select the language and use the follow account to log in to the MPGS system:

Account : admin

Password : 0.01mpgs

Importing the Parking Base Map

  • Open MPGS and click Parking Map.

You can build new project or import backup project map after then.

If there is an existing project already, you can download and export the map, delete it or continue to add.

After importing as below:

Import other layers here, or import later.

Drawing the Map

Notice:

First get familiar with the drwing instructions and hot keys in the map editor.

Pay attention to whether the hand shape is triggered when drawing the map. It is used to drag and zoom when it is triggered, or press the space bar to trigger the drag and zoom function. When the palm lights up, it means you are not in zoom mode.

Pay attention to whether it is locked, especially when drawing the map for several times. It cannot be edited after it is locked and needs to be unlocked. Green is unlocked.

Please note to hide the layer. It is impossible to be seen after hidden, but it is convenient for drawing the map.

Pay attention to save frequently to avoid unsuccessful saving of the map when the network is disconnected or other problems.

Save Data and Add Floors

Save it at intervals to avoid loss due to abnormalities.

If you need to add more floors, click here and import the corresponding drawings.

Edit Parking Space

First click on "Content" and the corresponding floor, and draw the parking spaces.

Click one parking space to come out, after canceling the click, adjust to a suitable size.

Associate the corresponding equipment, such as Ultrasonic Detector, and fill in the parking space number. The next point will automatically increase the parking space number.

Drag more parking spaces out, fill up the parking spaces in the car park, and fill in the parking space number. If the parking space number is unknown, leave it alone.

When placing the points, bind the corresponding equipment first, and then it is best to place them in the order of the parking space numbers, because after the first parking space number is filled in, the parking space numbers of the following points will increase by default.

Develop good habits and save occasionally to avoid data loss caused by network disconnection.

Editing LED Display

Place the display where you need to place and fill in the corresponding group address, sign address, font size and corresponding IP that you recorded in advance.

If using RS485 to connect the AKE RS485 display. Then the IP should fill in 127.0.0.1

For 18 type display, just fill in its 8-digits ID, no need to fill in the group address and sign address. 18 type display are in active reporting mode.

Bingding the Logic Area

What is a logic area?

The following picture shows a car park. The yellow is the road, the blue-gray box is the parking space, M and N are the indoor guidance displays, and P is the outdoor guidance display. Then we need to separate the areas of the car park. as follows:

M indoor guidance display: the parking space included in the left turn is A3, the right turn is A4, and the forward is A5+A6+A7.

N indoor guidance display: the parking space included in the left turn is A5, and the right turn is A6.

P outdoor guidance display: It displays the parking spaces of the whole car park, which is A1+A2+A3+A4+A5+A6+A7, or only 1 total area A8.

If defined the the logic zone of the car park on the first floor as A1,A2…… Then second floor will be B1,B2…… The area type is selected as "Guidance Area"

Click on the display, if you want the display to show "how many parking spaces to the left, how many parking spaces to the right", the operation steps: Click: "←, 888, add, 888, →, add" to achieve the following effect.

Bind the logical area: After clicking the binding area button, directly click the corresponding area on the map to increase. Each group of numbers can be associated with multiple areas to display its real-time parking space.

If you want to bind a cross-layer area, you can select in below directly.

Equipment Parameter Configuration in DMS

Enter the URL 127.0.0.1:8122 in the browser.

Select the language and use the follow account to log in to the DMS system:

Account: root Password: root123

LED Indoor(Non 18 Type) LED Display

After the MPGS parking map is drawn and saved, the corresponding information (IP, group address, sign address, etc.) will be brought to the DMS automatically.

If the display is connected and well communication, it will show online and you can send content by Device Debug.

Zonal Controller Debugging

Zonal Controller CUC-14RR as below:

There are 5 buttons under the LCD screen as below:

They are:

RESET | ESC | LEFT | SHIFT | ENTER

Enter the debugging interface: Long press ESC and ENTER, press RESET once, wait until the screen displays welcome, release ESC and ENTER, and then press ENTER will enter the administrator mode of the controller: press LEFT and SHIFT to switch its menu.

There are 4 menus in total :

Auto Check

Automatic inspection switch, default on, please don’t change.

Look over

Automatically loop view all the detector status.

Single check

Singlely check one certain detector status.

Setup address

Set the address for the controller.

If there are 8 controllers at site, edit their ID to 01~08 according to the drawings or install them in a certain order.

Adding Ultrasonic Detector in the Map

Ultrasonic detector will all use "ultrasonic detector" in the software.

The LED indicator is controlled by the ultrasonic detector, so there is no need to draw the LED indicator in the software.

Bind the ultrasonic detector to the parking space and fill in the ID of the ultrasonic detector. For example, if the zonal controller ID is 3 and the detector ID is 1, then the ultrasonic parkiong space address is 0301.

If the address of the parking space just filled in is 0301, then click to add the next parking space and click the "+" sign, and the 0302 address will be filled by default, which is convenient for quick drawing.

Adding the Zonal Controller to DMS

If using RS485 to connect the zonal controller. Then add equipment and fill in base on actual.

The factory default IP for RS485 linking is also 127.0.0.1

Address and port please also fill in actual.

According to the zonal controller and the ultrasonic detector it loads to add the corresponding element in the DMS ultrasonic module.

For example, the No. 3 zonal controller has loaded ultrasonic detectors 00-36, and the settings are as below.

If using Ethernet to connect the zonal controller. If the RS485 to ethernet convertor have been set and connected. The IP and port shall be filled in the actual convertor IP and port.

If the RS485 to ethernet converter have been set.

Under PUD, you can see the online status of each ultrasonic detector.

Adding Loop Detector in the Map

1. Add the loop detector in the DMS first.

2, Open the MPGS Map Editor and creat the DG AREA(loop detector area), input the related information. Then bingding the related loop detector to this DG AREA.

3, Creat the display in the map and input the related information. Bingding the DG AREA to this display.

4, Open the Car Park--Area Management--Set. Then you can set the total area parking spaces number and also the remaining parking spaces number(vacant parking spaces number).

5, You can also press the button of Timing Set. And in here you can set the rule that to set a specify remaining parking spaces number at the specified time (automatic calibration for loop detector area).

Configuration of RS485-to-Ethernet Converter for Ultrasonic

Different ethernet converter may be different setting, but the main parameters that need to be set are as follow:

Converter working mode: Station Mode

According to the server IP information, correspondingly modify the converter's IP and other information. Make sure the server/PC and the converter to be in the same IP segment.

(Note that you will see the place where the IP is filled only when you turn off DHCP)

The baud rate needs to be modified to 9600 and the buffer size to 1400

Please select the TCP SERVER protocol , the local port number please set to 5233(the same as the setting in DMS), and the buffer size please set to 1400.

🅰️
🚦