GS-002
Last updated
Was this helpful?
Last updated
Was this helpful?
For the use environment without eaves, you can quickly debug the barrier according to the following steps:
1
Set the up and down speed according to the type and length of the boom
Set the speed in H-02
2
Open and close the barrier gate several times to see if the barrier boom is stable
Press the open and close button of remote control to control the barrier gate
It is normal for the long boom to shake when you find the position for the first time
3
If the boom shakes when open and close the barrier gate
Fine-tune the parameters in F-00~F07
Refer to “5. Common Malfunctions and Solutions”
4
Adjust horizontal and vertical position
Fine-tune F-08 and F09
It can also be assisted by adjusting the connecting rod
F-00
Boom up speed
40
15-100
The larger the value, the faster the boom up speed
F-01
Boom down speed
40
15-100
The smaller the value, the faster the boom down speed
F-02
Boom up deceleration position
60
10-80
The angle at which the boom up starts to decelerate, unit: degrees
F-03
Boom down deceleration position
40
10-80
The angle at which the boom down starts to decelerate, unit: degrees
F-04
Low speed running angle for boom up
90
45-90
The angle of the last section of low-speed zone during boom up
F-05
Low speed running angle for boom down
0
0-45
The angle of the last section of low-speed zone during boom down
F-06
End speed for boom up
8
1-50
Boom up limit position speed
F-07
End speed for boom down
4
1-50
Boom down limit position speed
F-08
Horizontal position adjustment
15
1-255
Adjustment horizontal position of the barrier gate
F-09
Vertical position adjustment
6
1-99
Adjustment the vertical position of the barrier gate
F-10
Delay auto-closing time
0
0-99
Auto-closing time when no car passes, unit: seconds
F-11
Reserving
0
0-255
F-12
Reserving
0
0-255
F-13
Power-on self-learning speed
25
10-80
Find up and down limit at this speed
F-14
Remote controller learning
0
0-30
Learning remote control
F-15
Sensitivity of auto-reversing on obstruction
10
1-40
Obstruction response time, unit: 0.05 second
Long press button "" for 2 seconds to enter the general menu setting status, the digital tube will display "F-XX". Select menu items by short press or long press two buttons "▲ /+" and "▼ /-", short press once to increase or decrease by one, long press to continuously increase or decrease. When the "F-XX" item displayed by the digital tube is the parameter that needs to be set, press button "" again to enter the setting of the specified item, and press button "■ /QUIT" to return to the previous level or exit the setting. When the specified parameter setting is completed, you must press button "" to confirm it to take effect. The parameters currently set by pressing button "■ /QUIT" will not take effect