Wiring Diagram

Model DZE-BL Quick Debugging Guide

For the use environment without eaves, you can quickly debug the barrier according to the following steps:

Step
Name
Operation
Note

1

Set the up and down speed according to the type and length of the boom

Set the speed in H-02

2

Open and close the barrier gate several times to see if the barrier boom is stable

Press the open and close button of remote control to control the barrier gate

It is normal for the long boom to shake when you find the position for the first time

3

If the boom shakes when open and close the barrier gate

Fine-tune the parameters in F-00~F07

Refer to “5. Common Malfunctions and Solutions”

4

Adjust horizontal and vertical position

Fine-tune F-08 and F09

It can also be assisted by adjusting the connecting rod

Controller Menu Setting

Long press button "" for 2 seconds to enter the general menu setting status, the digital tube will display "F-XX". Select menu items by short press or long press two buttons "▲ /+" and "▼ /-", short press once to increase or decrease by one, long press to continuously increase or decrease. When the "F-XX" item displayed by the digital tube is the parameter that needs to be set, press button "" again to enter the setting of the specified item, and press button "■ /QUIT" to return to the previous level or exit the setting. When the specified parameter setting is completed, you must press button "" to confirm it to take effect. The parameters currently set by pressing button "■ /QUIT" will not take effect

"Regular Menu" Command List

Menu
Function
Defaults
Range
Remark

F-00

Boom up speed

40

15-100

The larger the value, the faster the boom up speed

F-01

Boom down speed

40

15-100

The smaller the value, the faster the boom down speed

F-02

Boom up deceleration position

60

10-80

The angle at which the boom up starts to decelerate, unit: degrees

F-03

Boom down deceleration position

40

10-80

The angle at which the boom down starts to decelerate, unit: degrees

F-04

Low speed running angle for boom up

90

45-90

The angle of the last section of low-speed zone during boom up

F-05

Low speed running angle for boom down

0

0-45

The angle of the last section of low-speed zone during boom down

F-06

End speed for boom up

8

1-50

Boom up limit position speed

F-07

End speed for boom down

4

1-50

Boom down limit position speed

F-08

Horizontal position adjustment

15

1-255

Adjustment horizontal position of the barrier gate

F-09

Vertical position adjustment

6

1-99

Adjustment the vertical position of the barrier gate

F-10

Delay auto-closing time

0

0-99

Auto-closing time when no car passes, unit: seconds

F-11

Reserving

0

0-255

F-12

Reserving

0

0-255

F-13

Power-on self-learning speed

25

10-80

Find up and down limit at this speed

F-14

Remote controller learning

0

0-30

Learning remote control

F-15

Sensitivity of auto-reversing on obstruction

10

1-40

Obstruction response time, unit: 0.05 second