Setting Parameters 24V DC Barrier Gate
Entry mode setting
Before setting, we should use password to enter. Password: Press ”SETTING”, display shows “Cd0”;then press “OPEN”, “CLOSE”, and “STOP” key one by one, each key only press one time; After this, press “SETTING” key to enter into parameter setting.
Standard parameters setting (P01-P22)
P01 : Set boom type and length
Pls press "setting" key to "P00"
Press "open" or "close" key to "P01"
Press "setting" key to "b-x" ( "x" means boom type, =0: straight boom with rubber; =1: straight boom; =2:telescopic boom;=3: two-fence boom; =4: 3-fence boom; =5:advertising boom)
Press "open" or "close" key to choose right boom type(take telescopic arm as example “b-2”);
Press "setting" key, display will shows "2a.b" (a.b means boom length), press "open" or "close" to set right arm length(take 3.5 meters telescopic arm as example, we should set it to be “23.5”)
After setting, press "setting" key, display shows "P01"
Press "stop" key to exit and confirm all settings
P02 : Set open speed
Pls press "setting" key to "P00"
Press "open" or "close" key to "P02"
Press "setting" key, display shows "OPX" ( "x" means open speed value )
Press "open" or "close" key to choose "X" value (If ensure the value)
Press "setting" key to "P02"
Press "stop" key to exit (Pls refer to 3.5 of Equipment Debugging)
P03 : Set close speed
Pls press "setting" key to "P00"
Press "open" or "close" key to "P03"
Press "setting" key to "OPX" ( "x" means open speed value )
Press "open" or "close" key to choose "X" value (If ensure the value)
Press "setting" key to "P03"
Press "stop" key to exit (Pls refer to 3.6 of Equipment Debugging) Pls note, the speed should match the corresponding boom length range)
P04 : Set fully open boom position
Pls press "setting" key to "P00"
Press "open" or "close" key to "P04"
Press "setting" key to "XXX" (the value is corresponding with boom arm open position, it's relative, not absolute)
Press "open" or "close" key to adjust arm position (Press "open"/"close" key, arm will run toward open/close direction, encoder angle value also changes accordingly)
Press "setting" key to "P04"
Press "stop" key
Press "stop" and "open" key together to exit
P05 : Set fully close boom position
Pls press "setting" key to "P00"
Press "open" or "close" key to "P05"
Press "setting" key to "XXX" (the value is corresponding with boom arm open position, it's relative, not absolute)
Press "open" or "close" key to adjust arm position (Press "open"/"close" key, arm will run toward open/close direction, encoder angle value also changes accordingly)
Press "setting" key to "P05"
Press "stop" key
Press "stop" and "open" key together to exit
P09 : Set slow down parameter during open
Pls press "setting" key to "P00"
Press "open" or "close" key to "P09"
Press "setting" key for four times
Press "setting" key to "P09"
Press "stop" key to exit
P10 : Set slow down parameter during close
Pls press "setting" key to "P00"
Press "open" or "close" key to "P10"
Press "setting" key for four times
Press "setting" key to "P10"
Press "stop" key to exit
P18 : Set slow stable parameter during open
Pls press "setting" key to "P00"
Press "open" or "close" key to "P18"
Press "setting" key to "UXX" (XX means stable number,range:0-20)
Press "open" or "close" key to choose the number
Press "setting" key to "P18"
Press "stop" key to exit
P19 : Set slow stable parameter during close
Pls press "setting" key to "P00"
Press "open" or "close" key to "P19"
Press "setting" key to "UXX" (XX means stable number,range:0-20)
Press "open" or "close" key to choose the number
Press "setting" key to "P19"
Press "stop" key to exit
P20 : Set auto close time
Pls press "setting" key to "P00"
Press "open" or "close" key to "P20"
Press "setting" key to "0XX" (XX means the delay close time, range 0 -60s; default value:0)
Press "open" or "close" key to adjust the time
Press "setting" key to "P20"
Press "stop" key to exit
Hotkey illustration
Press “STOP” + “ OPEN” key: Set open limited position by hands
Use handle to turn the motor till boom on right open position, press “STOP’ key, but not loosen, then press “OPEN” key together, display shows “U--”, loosen “OPEN” key and “STOP” key one by one. then we can hear about 1s buzzing noise, setting finished.(the setting is supplement way if auto set open limited position isn’t good.) 2.Press “STOP” +”CLOSE” key: Set close limited position Use handle to turn the motor till boom on right close position, press “STOP’ key, but not loosen, then press “CLOSE” key together, display shows “d----”, loosen “CLOSE” key and “STOP” key one by one. then hear about 1s buzzing noise, setting finished. (the setting is supplement way if auto set close limited position isn’t good.)
Press “STOP” +”CLOSE” key: Set close limited position
Use handle to turn the motor till boom on right close position, press “STOP’ key, but not loosen, then press “CLOSE” key together, display shows “d----”, loosen “CLOSE” key and “STOP” key one by one. then hear about 1s buzzing noise, setting finished. (the setting is supplement way if auto set close limited position isn’t good.)
Press “STOP” +”OPEN” + “CLOSE” key”: Auto set open and close limited position
Press “STOP” key, but don’t loosen, then press “OPEN” and “CLOSE” key together, display shows “Ud-”, then loosen “OPEN” and “CLOSE” key, then loose “STOP” key, then we can hear about 1s buzzing noise. Barrier start to auto set open and close position:
First :> barrier auto-set open limited position, display shows “0P-”, it means barrier is setting open limited position; Second :> barrier auto-set close limited position, display shows “CL-”, it means barrier is setting close limited position.
Setting parameter when we change new function board
We must setting function board parameters if we change a broken board. Setting steps:
Press “SETTING” key and don’t loosen it;
Connect power till display “Cd0”
Input password: press “OPEN”, “CLOSE”, and “STOP” key one by one, each key only press one time, till display shows “Cd3”
Press “SETTING” key, display shows ”0--”.If barrier gate is left-hand version, press “SETTING” key directly to confirm; If barrier gate is right hand version, press ” OPEN” key, display shows”—0”, then press “SETTING” key to confirm;
Then display shows “b-x”, ”x” means boom type (=0: straight boom with rubber; =1:straight boom; =2:telescopic boom,;=3: two-fence boom; =4: 3-fence boom; =5:advertising boom), press “OPEN” or “CLOSE” key to choose boom type; After choosing the boom type, press ”SETTING” to confirm;
Then display shows “xa.b”, “x “means boom type, ”a.b “ means boom length (for example 23.0: 2 means telescopic boom; 3.0 means 3 meters boom), press “OPEN” or “CLOSE” key to choose boom length; After choosing the boom length, press ”SETTING” to confirm;
If display shows“F-0”,we should check barrier status: OPEN or CLOSE OPEN STATUS: press “Close” key and don’t loosen, if motor works. Then press ”SETTING” key, display shows “000”, then press ”SETTING” key, function board will run STEP 8 automatically; if motor doesn’t work, then press ”SETTING” key, display shows “000”, we should press “OPEN” key one time, display shows”001”. Then press ”SETTING” key, function board will run STEP 8 automatically. CLOSE STATUS: press ”OPEN” key, and don’t loosen, if motor works. Then press ”SETTING” key, display shows “000”, then press ”SETTING” key, function board will run STEP 8 automatically; if motor doesn’t work, then press ”SETTING” key, display shows “000”, we should press “OPEN” key one time, display shows”001”. Then press ”SETTING” key, function board will run STEP 8 automatically.
If display shows “F-1”, we should check barrier status: OPEN or CLOSE OPEN STATUS: press “Close” key and don’t loosen, if motor works. Then press ”SETTING” key, display shows “001”, then press ”SETTING” key, function board will run STEP 8 automatically; if motor doesn’t work, then press ”SETTING” key, display shows “001”, we should press “CLOSE” key one time, display shows”000”. Then press ”SETTING” key, function board will run STEP 8 automatically. CLOSE STATUS: press ”OPEN” key, and don’t loosen, if motor works. Then press ”SETTING” key, display shows “001”, then press ”SETTING” key, function board will run STEP 8 automatically; if motor doesn’t work, then press ”SETTING” key, display shows “001”, we should press “CLOSE” key one time, display shows”000”. Then press ”SETTING” key, function board will run STEP 8 automatically.
Then barrier gate will auto set limited position