Buku Mantra & Sihir
Peralatan SihirTrik Sihir
  • 🗺️Resep Sihir
  • 🅿️PARKING SYSTEM
    • 🏞️CPMS & POS
      • 🏂Showcase
        • QR BAG - Asia Parking
        • Update lisensi sistem parkir CPMS
        • FINNET-QRIS
        • Settlement Setoran
        • Size
      • 🧩Releases
    • Dashboard CPMS
    • 🎫E-Ticketing
    • 🚘Carlist
      • Installation
    • 🪨Harrcon System
      • Instalasi Software
    • 🗻Reserve Parking Standalone (BROMO)
      • ✍️Wiring HPPC Controller
      • 📒Manual Bromo
    • 🔓Parking Lock
      • IOT Parking Lock V.1.0.0 1
  • 🏡CASS
    • 🎗️CASS Premium
      • 🐟Aplikasi putar iklan
    • 🦕CASS VIP
      • Struktur Menu GAMA
      • Manual GAMA CASS VIP
    • 📮Cass Center
      • 🗄️Mini CASS
    • 🏕️Add On Tamu
      • 🌅Summarecon Gold Member
      • ⛵Open Gate Asia Parking
      • 🛡️Setup Server Paramount
      • 🔥API Paramount
      • 🔥API Citra Garden Puri
      • 🔥API Emerald Sepatan
      • 🔥API Neo Catalonia
      • 🔥API Castilla
  • 🛅GATE
    • 💣BOOM
      • 🚪Access PRO
        • Switch MPH1 ke MPH2 dengan Tool
      • 🚪MX
      • 🚪GS-001
        • ✍️Wiring
        • ⚙️Setting Parameters
      • 🚪GS-002
  • 🔢DDS
    • 6️⃣DDS Link
    • 7️⃣DDS LOOP
      • DDS Counter ICPCON
      • AUTOSTART SERVICE ICPCO
      • GOP Service Loop
      • SOP
  • 🎥CCTV
    • 📷LPR
      • Upgrade Firmware LPR TCG227 (SAHP227)
      • DS-TCG227
    • ⏺️NVR
  • 🚢SENSOR
    • 🤳Radar
      • Instalasi Radar
      • Wiring Diagram
      • Setting Parameter
    • 🪜Laser
      • 🛣️Comark LSR2001
  • 📶NETWORKING
    • 📻Radio
      • ♟️UBIQUITI
    • 🛶Mikrotik
      • Monitoring perangkat lewat Telegram [NETWATCH]
  • 🅰️AKE
    • 🚦MPGS
      • SDC-22NRS Data Server Simple Instructions
      • Adding Zonal Controller CUC-14RR and Ultrasonic Detector in DMS
      • MPGS Software Debug Manual Ultrasonic Solution
      • MPGS System API v3.6
      • Buat Map MPGS dengan Deep Zoom Composer
      • LED 18 Debug Tool
  • 🥪Reader
    • ♋Scanner QR
      • 🇮🇩Scanner SAP
      • 🦓Scanner Zebra
        • General
      • 🌒Scanner Codeshop
        • Format Code
    • 🍡DG-800
      • Features
      • Specification
      • Indicator Status & Default Setting Parameters
      • Wiring Diagram
      • Operation Instruction
  • 🎛️CONTROLLER
    • FALCO
      • [FALCO] This account has been locked or disabled for security reasons !
      • General
  • 🪄Trik Sihir
    • SupportX Apps
      • Panel Admin
        • Reports
          • Summary Outstanding
      • Panel Support
      • Changelogs
    • UnFaedah
      • Rescuezilla – Backup & Restore Software
    • Windows
      • Install Offline NET Framework 3.5 on Windows
      • Failed to install .Net Framework due to certificate could not verified
      • Meinberg NTP
      • 2 Cara Aktivasi Windows 10 Permanen GRATIS (100% Work)
      • Page 1
    • CentOS 7
      • Install Apache Web Server di CentOS 7
      • Install PHP 7.4 di CentOS 7
      • Install Mariadb 10.4 di CentOS 7
      • Open Port MySQL dan SSH
      • Install Server CentOS 7, MySQL with GUI
      • Can't find a valid base url for repo: base/7/x86_64
      • Setup Server Manless
    • Ubuntu
      • Install MySQL 5.7.* on Ubuntu 22.04, 24.04 dan 25.04
Powered by GitBook
On this page
  • Entry mode setting
  • Standard parameters setting (P01-P22)
  • P01 : Set boom type and length
  • P02 : Set open speed
  • P03 : Set close speed
  • P04 : Set fully open boom position
  • P05 : Set fully close boom position
  • P09 : Set slow down parameter during open
  • P10 : Set slow down parameter during close
  • P18 : Set slow stable parameter during open
  • P19 : Set slow stable parameter during close
  • P20 : Set auto close time
  • Hotkey illustration
  • Press “STOP” + “ OPEN” key: Set open limited position by hands
  • Press “STOP” +”CLOSE” key: Set close limited position
  • Press “STOP” +”OPEN” + “CLOSE” key”: Auto set open and close limited position
  • Setting parameter when we change new function board

Was this helpful?

  1. GATE
  2. BOOM
  3. GS-001

Setting Parameters

Setting Parameters 24V DC Barrier Gate

Entry mode setting

Before setting, we should use password to enter. Password: Press ”SETTING”, display shows “Cd0”;then press “OPEN”, “CLOSE”, and “STOP” key one by one, each key only press one time; After this, press “SETTING” key to enter into parameter setting.

Standard parameters setting (P01-P22)

P01 : Set boom type and length

  1. Pls press "setting" key to "P00"

  2. Press "open" or "close" key to "P01"

  3. Press "setting" key to "b-x" ( "x" means boom type, =0: straight boom with rubber; =1: straight boom; =2:telescopic boom;=3: two-fence boom; =4: 3-fence boom; =5:advertising boom)

  4. Press "open" or "close" key to choose right boom type(take telescopic arm as example “b-2”);

  5. Press "setting" key, display will shows "2a.b" (a.b means boom length), press "open" or "close" to set right arm length(take 3.5 meters telescopic arm as example, we should set it to be “23.5”)

  6. After setting, press "setting" key, display shows "P01"

  7. Press "stop" key to exit and confirm all settings

P02 : Set open speed

  1. Pls press "setting" key to "P00"

  2. Press "open" or "close" key to "P02"

  3. Press "setting" key, display shows "OPX" ( "x" means open speed value )

  4. Press "open" or "close" key to choose "X" value (If ensure the value)

  5. Press "setting" key to "P02"

  6. Press "stop" key to exit (Pls refer to 3.5 of Equipment Debugging)

P03 : Set close speed

  1. Pls press "setting" key to "P00"

  2. Press "open" or "close" key to "P03"

  3. Press "setting" key to "OPX" ( "x" means open speed value )

  4. Press "open" or "close" key to choose "X" value (If ensure the value)

  5. Press "setting" key to "P03"

  6. Press "stop" key to exit (Pls refer to 3.6 of Equipment Debugging) Pls note, the speed should match the corresponding boom length range)

P04 : Set fully open boom position

  1. Pls press "setting" key to "P00"

  2. Press "open" or "close" key to "P04"

  3. Press "setting" key to "XXX" (the value is corresponding with boom arm open position, it's relative, not absolute)

  4. Press "open" or "close" key to adjust arm position (Press "open"/"close" key, arm will run toward open/close direction, encoder angle value also changes accordingly)

  5. Press "setting" key to "P04"

  6. Press "stop" key

  7. Press "stop" and "open" key together to exit

P05 : Set fully close boom position

  1. Pls press "setting" key to "P00"

  2. Press "open" or "close" key to "P05"

  3. Press "setting" key to "XXX" (the value is corresponding with boom arm open position, it's relative, not absolute)

  4. Press "open" or "close" key to adjust arm position (Press "open"/"close" key, arm will run toward open/close direction, encoder angle value also changes accordingly)

  5. Press "setting" key to "P05"

  6. Press "stop" key

  7. Press "stop" and "open" key together to exit

P09 : Set slow down parameter during open

  1. Pls press "setting" key to "P00"

  2. Press "open" or "close" key to "P09"

  3. Press "setting" key for four times

  4. Press "setting" key to "P09"

  5. Press "stop" key to exit

P10 : Set slow down parameter during close

  1. Pls press "setting" key to "P00"

  2. Press "open" or "close" key to "P10"

  3. Press "setting" key for four times

  4. Press "setting" key to "P10"

  5. Press "stop" key to exit

P18 : Set slow stable parameter during open

  1. Pls press "setting" key to "P00"

  2. Press "open" or "close" key to "P18"

  3. Press "setting" key to "UXX" (XX means stable number,range:0-20)

  4. Press "open" or "close" key to choose the number

  5. Press "setting" key to "P18"

  6. Press "stop" key to exit

P19 : Set slow stable parameter during close

  1. Pls press "setting" key to "P00"

  2. Press "open" or "close" key to "P19"

  3. Press "setting" key to "UXX" (XX means stable number,range:0-20)

  4. Press "open" or "close" key to choose the number

  5. Press "setting" key to "P19"

  6. Press "stop" key to exit

P20 : Set auto close time

  1. Pls press "setting" key to "P00"

  2. Press "open" or "close" key to "P20"

  3. Press "setting" key to "0XX" (XX means the delay close time, range 0 -60s; default value:0)

  4. Press "open" or "close" key to adjust the time

  5. Press "setting" key to "P20"

  6. Press "stop" key to exit

Hotkey illustration

Press “STOP” + “ OPEN” key: Set open limited position by hands

Use handle to turn the motor till boom on right open position, press “STOP’ key, but not loosen, then press “OPEN” key together, display shows “U--”, loosen “OPEN” key and “STOP” key one by one. then we can hear about 1s buzzing noise, setting finished.(the setting is supplement way if auto set open limited position isn’t good.) 2.Press “STOP” +”CLOSE” key: Set close limited position Use handle to turn the motor till boom on right close position, press “STOP’ key, but not loosen, then press “CLOSE” key together, display shows “d----”, loosen “CLOSE” key and “STOP” key one by one. then hear about 1s buzzing noise, setting finished. (the setting is supplement way if auto set close limited position isn’t good.)

Press “STOP” +”CLOSE” key: Set close limited position

Use handle to turn the motor till boom on right close position, press “STOP’ key, but not loosen, then press “CLOSE” key together, display shows “d----”, loosen “CLOSE” key and “STOP” key one by one. then hear about 1s buzzing noise, setting finished. (the setting is supplement way if auto set close limited position isn’t good.)

Press “STOP” +”OPEN” + “CLOSE” key”: Auto set open and close limited position

Press “STOP” key, but don’t loosen, then press “OPEN” and “CLOSE” key together, display shows “Ud-”, then loosen “OPEN” and “CLOSE” key, then loose “STOP” key, then we can hear about 1s buzzing noise. Barrier start to auto set open and close position:

First :> barrier auto-set open limited position, display shows “0P-”, it means barrier is setting open limited position; Second :> barrier auto-set close limited position, display shows “CL-”, it means barrier is setting close limited position.

During the process, the only way to stop the barrier is to press “STOP” button.

Setting parameter when we change new function board

We must setting function board parameters if we change a broken board. Setting steps:

  1. Press “SETTING” key and don’t loosen it;

  2. Connect power till display “Cd0”

  3. Input password: press “OPEN”, “CLOSE”, and “STOP” key one by one, each key only press one time, till display shows “Cd3”

  4. Press “SETTING” key, display shows ”0--”.If barrier gate is left-hand version, press “SETTING” key directly to confirm; If barrier gate is right hand version, press ” OPEN” key, display shows”—0”, then press “SETTING” key to confirm;

  5. Then display shows “b-x”, ”x” means boom type (=0: straight boom with rubber; =1:straight boom; =2:telescopic boom,;=3: two-fence boom; =4: 3-fence boom; =5:advertising boom), press “OPEN” or “CLOSE” key to choose boom type; After choosing the boom type, press ”SETTING” to confirm;

  6. Then display shows “xa.b”, “x “means boom type, ”a.b “ means boom length (for example 23.0: 2 means telescopic boom; 3.0 means 3 meters boom), press “OPEN” or “CLOSE” key to choose boom length; After choosing the boom length, press ”SETTING” to confirm;

  7. If display shows“F-0”,we should check barrier status: OPEN or CLOSE OPEN STATUS: press “Close” key and don’t loosen, if motor works. Then press ”SETTING” key, display shows “000”, then press ”SETTING” key, function board will run STEP 8 automatically; if motor doesn’t work, then press ”SETTING” key, display shows “000”, we should press “OPEN” key one time, display shows”001”. Then press ”SETTING” key, function board will run STEP 8 automatically. CLOSE STATUS: press ”OPEN” key, and don’t loosen, if motor works. Then press ”SETTING” key, display shows “000”, then press ”SETTING” key, function board will run STEP 8 automatically; if motor doesn’t work, then press ”SETTING” key, display shows “000”, we should press “OPEN” key one time, display shows”001”. Then press ”SETTING” key, function board will run STEP 8 automatically.

  8. If display shows “F-1”, we should check barrier status: OPEN or CLOSE OPEN STATUS: press “Close” key and don’t loosen, if motor works. Then press ”SETTING” key, display shows “001”, then press ”SETTING” key, function board will run STEP 8 automatically; if motor doesn’t work, then press ”SETTING” key, display shows “001”, we should press “CLOSE” key one time, display shows”000”. Then press ”SETTING” key, function board will run STEP 8 automatically. CLOSE STATUS: press ”OPEN” key, and don’t loosen, if motor works. Then press ”SETTING” key, display shows “001”, then press ”SETTING” key, function board will run STEP 8 automatically; if motor doesn’t work, then press ”SETTING” key, display shows “001”, we should press “CLOSE” key one time, display shows”000”. Then press ”SETTING” key, function board will run STEP 8 automatically.

  9. Then barrier gate will auto set limited position

PreviousWiringNextGS-002