> For the complete documentation index, see [llms.txt](https://supportx.gitbook.io/buku-mantra-and-sihir/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://supportx.gitbook.io/buku-mantra-and-sihir/gate/boom/gs-002.md).

# GS-002

### Wiring Diagram

<figure><img src="https://1731165174-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FtQJu2Q0LuwmDBRrVlRsJ%2Fuploads%2FdFqmLL93b7hLyOj5C2yW%2Fimage.png?alt=media&amp;token=e1e4ab4f-abe7-418f-a6fc-10511b685185" alt="" width="556"><figcaption></figcaption></figure>

### Model DZE-BL Quick Debugging Guide

For the use environment without eaves, you can quickly debug the barrier according to the following steps:

<table><thead><tr><th width="100">Step</th><th>Name</th><th>Operation</th><th>Note</th></tr></thead><tbody><tr><td>1</td><td><br>Set the up and down speed according to the type and length of the boom</td><td>Set the speed in H-02<br></td><td></td></tr><tr><td>2</td><td>Open and close the barrier gate several times to see if the barrier boom is stable</td><td>Press the open and close button of remote control to control the barrier gate</td><td>It is normal for the long boom to shake when you find the position for the first time</td></tr><tr><td>3</td><td>If the boom shakes when open and close the barrier gate</td><td>Fine-tune the parameters in F-00~F07</td><td>Refer to “5. Common Malfunctions and Solutions”</td></tr><tr><td>4</td><td>Adjust horizontal and vertical position</td><td>Fine-tune F-08 and F09</td><td>It can also be assisted by adjusting the connecting rod</td></tr></tbody></table>

### Controller Menu Setting

Long press button "![](https://1731165174-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FtQJu2Q0LuwmDBRrVlRsJ%2Fuploads%2FfMEcR08T0NhHsvY7VCbt%2Fimage.png?alt=media\&token=371205d7-bd09-40b0-af63-b26692f13997)" for 2 seconds to enter the general menu setting status, the digital tube will display "F-XX". Select menu items by short press or long press two buttons "▲ /+" and "▼ /-", short press once to increase or decrease by one, long press to continuously increase or decrease. When the "F-XX" item displayed by the digital tube is the parameter that needs to be set, press button "![](https://1731165174-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FtQJu2Q0LuwmDBRrVlRsJ%2Fuploads%2FfMEcR08T0NhHsvY7VCbt%2Fimage.png?alt=media\&token=371205d7-bd09-40b0-af63-b26692f13997)" again to enter the setting of the specified item, and press button "■ /QUIT" to return to the previous level or exit the setting. When the specified parameter setting is completed, you must press button "![](https://1731165174-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FtQJu2Q0LuwmDBRrVlRsJ%2Fuploads%2FfMEcR08T0NhHsvY7VCbt%2Fimage.png?alt=media\&token=371205d7-bd09-40b0-af63-b26692f13997)" to confirm it to take effect. The parameters currently set by pressing button "■ /QUIT" will not take effect

### "Regular Menu" Command List

<table><thead><tr><th width="100">Menu</th><th>Function</th><th width="100">Defaults</th><th width="100">Range</th><th>Remark</th></tr></thead><tbody><tr><td>F-00</td><td>Boom up speed</td><td>40</td><td>15-100</td><td>The larger the value, the faster the boom up speed</td></tr><tr><td>F-01</td><td>Boom down speed</td><td>40</td><td>15-100</td><td>The smaller the value, the faster the boom down speed</td></tr><tr><td>F-02</td><td>Boom up deceleration position</td><td>60</td><td>10-80</td><td>The angle at which the boom up starts to decelerate, unit: degrees</td></tr><tr><td>F-03</td><td>Boom down deceleration position</td><td>40</td><td>10-80</td><td>The angle at which the boom down starts to decelerate, unit: degrees</td></tr><tr><td>F-04</td><td>Low speed running angle for boom up</td><td>90</td><td>45-90</td><td>The angle of the last section of low-speed zone during boom up</td></tr><tr><td>F-05</td><td>Low speed running angle for boom down</td><td>0</td><td>0-45</td><td>The angle of the last section of low-speed zone during boom down</td></tr><tr><td>F-06</td><td>End speed for boom up</td><td>8</td><td>1-50</td><td>Boom up limit position speed</td></tr><tr><td>F-07</td><td>End speed for boom down</td><td>4</td><td>1-50</td><td>Boom down limit position speed</td></tr><tr><td>F-08</td><td>Horizontal position adjustment</td><td>15</td><td>1-255</td><td>Adjustment horizontal position of the barrier gate</td></tr><tr><td>F-09</td><td>Vertical position adjustment</td><td>6</td><td>1-99</td><td>Adjustment the vertical position of the barrier gate</td></tr><tr><td>F-10</td><td>Delay auto-closing time</td><td>0</td><td>0-99</td><td>Auto-closing time when no car passes, unit: seconds</td></tr><tr><td>F-11</td><td>Reserving</td><td>0</td><td>0-255</td><td></td></tr><tr><td>F-12</td><td>Reserving</td><td>0</td><td>0-255</td><td></td></tr><tr><td>F-13</td><td>Power-on self-learning speed</td><td>25</td><td>10-80</td><td>Find up and down limit at this speed</td></tr><tr><td>F-14</td><td>Remote controller learning</td><td>0</td><td>0-30</td><td>Learning remote control</td></tr><tr><td>F-15</td><td>Sensitivity of auto-reversing on obstruction</td><td>10</td><td>1-40</td><td>Obstruction response time, unit: 0.05 second</td></tr></tbody></table>